Abstract
Purpose: This study aims to highlight presentations, acute findings and imaging phenotypes of patients presenting to the emergency department (ED) within 30 days of a transcatheter aortic valve replacement (TAVR). Methods: A retrospective review of patients diagnosed with aortic valve disease who underwent a TAVR between Jan 2015 and Nov 2021 at a large academic medical center was completed. From an initial 1271 patients, 146 were included based on their presentation to the ED within 30 days post-TAVR procedure. Patient data, including ED presentation details and imaging results, were recorded and de-identified. Results: Of the 146 post-TAVR patients, there were 168 ED visits within 30 days. The median time to ED after TAVR was 12 days. Respiratory symptoms were the most common complaint (27%). Neurological (23%) and cardiovascular symptoms (18%) followed. Cross-sectional imaging was conducted 250 times across visits, with an average of 1.7 scans per patient. CTs were most frequently used, followed by ultrasounds, especially echocardiograms and duplex extremity vasculature ultrasounds. 30.1% of patients had acute findings from imaging. Specific findings included heart failure (5.5%), access site complications (5.5%), pneumonia (5.5%), intracranial pathologies (3.4% for strokes and 0.7% for hematoma), and pleural effusion (3.4%). Echocardiograms and CTA chest were most associated with significant acute findings. Conclusion: Our study highlights the vital role of early and accurate imaging in post-TAVR patients within 30 days post-procedure. As transcatheter approaches rise in popularity, emergency radiologists become instrumental in diagnosing common post-procedural presentations. Continued research is essential to devise post-discharge strategies to curtail readmissions and related costs. Proper imaging ensures prompt, effective care, enhancing overall patient outcomes.
Keywords
complications, computed tomography, emergency department readmissions, magnetic resonance imaging, nuclear imaging, transcatheter aortic valve replacement, ultrasound
Publication Title
Emergency Radiology
Rights
© The Author(s) 2024. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
Recommended Citation
Chau, E., Mew, A., Bera, K. et al. Emergency department imaging utilization post-transcatheter aortic valve replacement: single institution 7-year experience. Emerg Radiol 31, 349–357 (2024). https://doi.org/10.1007/s10140-024-02228-y